女浴室里赤裸裸洗澡丰满视频,多毛熟女HDVIDOS,国产精品成人一区二区三区,驯服人妻HD中字日本

技術中心

上海信帆代理銷售褪黑素放免檢測服務(DIA Source)

2015年06月08日 10:04:57人氣:1355來源:信帆生物

資料類型pdf文件資料大小404226
下載次數38資料圖片 【點擊查看】
上 傳 人信帆生物 需要積分0
關 鍵 詞褪黑素放免檢測服務
【資料簡介】

上海信帆代理銷售褪黑素放免檢測服務(DIA Source),歡迎。

比利時DIA Source公司主要經營放免檢測服務,ELISA試劑盒,我們致力于制造用于診斷和檢測各種內分泌紊亂疾病的ELISA和RIA的手工操作免疫測定試劑盒。同時不斷地改良并發展用于診斷試劑的特殊抗體,也為其他試劑企業提供此類抗體。

Melatonin Saliva Direct RIA
1. Introduction
1.1 Intended use and principle of the test
125I – Radioimmunoassay for the direct quantitative determination of melatonin in saliva.
The assay procedure follows the basic principle of radioimmunoassay, involving competition between a
radioactive and a non-radioactive antigen for a fixed number of antibody binding sites. When the system
is in equilibrium, the antibody bound radioactivity is precipitated with a second antibody in the presence
of polyethylene glycol. After centrifugation and decantation of the supernatant the precipitate is counted
in a gamma counter. The amount of 125I-labelled antigen bound to the antibody is inversely proportional
to the analyte concentration of the sample. Quantification of unknown samples is achieved by comparing
their activity with a reference curve prepared with known standards.
1.2 Clinical application
In mammals, melatonin is biosynthesized in the pineal gland from the essential dietary amino acid
tryptophan, with serotonin produced as an intermediate. In general melatonin acts as an endocrine
hormone playing a key role in the regulation of the biorhythm.
The serum and saliva melatonin levels in humans show a marked circadian rhythm characterized by very
low levels during day time and high levels during night time.
Altered patterns and/or levels of melatonin secretion have been reported to coincide with sleep disorders,
jet lag, depression, stress, schizophrenia, hypothalamic amenorrhea, pregnancy, anorexia nervosa, some
forms of cancer, immunological disorders as well as control of sexual maturation during puberty.
Many biological effects of melatonin are generated through activation of melatonin receptors, while others
are due to its role as a powerful scavenger for free radicals in the human body.
Therapeutic consequences should never be based on laboratory results alone even if all test results are in
agreement with the items as under point “Procedural cautions, guidelines and warnings”. Any laboratory
result is only a part of the total clinical picture of the patient.
Only in cases where the laboratory results are in an acceptable agreement with the overall clinical picture
of the patient it can be used for therapeutic consequences.
The test result itself should never be the sole determinant for deriving any therapeutic consequences.
2. Procedural cautions, guidelines, warnings and limitations
2.1 Precautions, guidelines and warnings
(1) This kit is intended for professional use only. Users should have a thorough understanding of this protocol
for the successful use of this kit. Only the test instruction provided with the kit is valid and has to be used
to run the assay. Reliable performance will only be attained by strict and careful adherence to the
instructions provided.
(2) This assay was validated for certain types of samples as indicated in Intended Use (please refer to
Chapter 1). Any off-label use of this kit is in the responsibility of the user and the manufacturer cannot be
held liable.
(3) Reagents of this kit which contain human serum or plasma have been tested and confirmed negative for
HIV I/II, HBsAg and HCV by approved procedures. All reagents, however, should be treated as potential
biohazards in use and for disposal.
(4) The principles of Good Laboratory Practice (GLP) have to be followed.
(5) In order to reduce exposure to potentially harmful substances, wear lab coats, disposable protective
gloves and protective glasses where necessary.
(6) All kit reagents and specimens should be brought to room temperature and mixed gently but thoroughly
before use. Avoid repeated freezing and thawing of reagents and specimens.
(7) For the dilution or reconstitution purposes use deionized, distilled, or ultra-pure water.
(8) The radioactive material (125Iodine, half life 60 days, emitting ionizing X-radiation with 28 keV and Gradiation
with 35.5 keV) may be received, acquired, possessed and used only by physicians, laboratories
or hospitals. In compliance with regulations, a copy of the customer’s current radioisotope license must
be on file with the supplier. Orders cannot be shipped until the license is received by the supplier
(Radiation Protection Act of June 30, 1989).
(9) Duplicate determination of sample is highly recommended to be able to identify potential pipetting errors.
(10) Once the test has been started, all steps should be completed without interruption. Make sure that the
required reagents, materials and devices are prepared ready at the appropriate time.
(11) Incubation times do influence the results. All tubes should be handled in the same order and time
intervals.
(12) To avoid cross-contamination of reagents, use new disposable pipette tips for dispensing each reagent,
sample, standard and control.


信帆生物作者

上一篇:BURKERT截止閥特點既優勢與劣勢

下一篇:festo費斯托減壓閥幾個方面詳細介紹


我要投稿
  • 投稿請發送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
  • 聯系電話0571-87759680
環保行業“互聯網+”服務平臺
環保在線APP

功能豐富 實時交流

環保在線小程序

訂閱獲取更多服務

微信公眾號

關注我們

抖音

環保在線網

抖音號:hbzhan

打開抖音 搜索頁掃一掃

視頻號

環保在線

公眾號:環保在線

打開微信掃碼關注視頻號

快手

環保在線

快手ID:2537047074

打開快手 掃一掃關注
意見反饋